FEATURES
The Operate/Maintain module is designed to capture the in-service performance of protective systems and functions and associated devices within a processing facility, and report on the history and status of these entities. Data captured over time allows managers to identify performance trends and address any discovered problems. System users can easily define Test Procedures for the protective systems and begin recording test data immediately. The Operate Maintain module uses device event data to compile and generate prior use data and subsequent reliability statics.
- Failure analysis and demand tracking
- Overdue test tracking
- Turnaround test tracking
- Barrier bypass/override risk assessments
- Maintenance proof test results and tracking
- Key performance indicators and dashboards
- Configure instant reports (weekly, monthly) to organization standards
- Compile event data over time into prior use data
- Inspection and maintenance planning
- Workflows for documenting: Bypass/Override Procedure, Demand Events, Fault/Failure Reporting, Preventive Maintenance Result Reports and Test Events
- API-RP-754 Tier III Metrics are implemented as a way of tracking challenges to safety systems, such as measures to log large consequence events
- Main Dashboard presents a widget-based selection of KPIs/Reports displayed as windowpanes that default to the user’s account role
- Approval Workflow for Event feature allows Personnel objects associated with a user account to approve or reject events through a series of steps
- Administration reporting available for executing data curing to highlight and enter missing data necessary for optimizing operations data reporting and KPI generation
- A myriad of general, operational, and testing reports provides thorough views of organized and compiled operations data with navigation links to instantly open specific and more granular data
- Categorization of reports allows for quick grouping and simplification of more than 60 basic reports to keep report navigation organized and effortless
- Organize Pending Approvals into a single page view that summarizes all the Pending Events at various levels of the organization
- Automatic periodic statistic updating refreshes data fields related to Testing and Performance of protective systems and their instrument components
- Test Event Workflows allow Functions and Devices to be tested independently from each other
- Integrate protective systems and components with data historians such as PI to automate capturing of real-time events such as demands and bypasses for immediately observed effects on performance and reliability of documented systems
Data & Reports
SLM V2 OPERATE AND MAINTAIN DATA & REPORTS
The following Data and Reports are part of the SLM V2 core Operate and Maintain Module.
Data:
- Overview
- Enterprise Overview
- SIS List
- Functions and Events
- Bypass Summary
- Test Summary
- Demand Summary
- Fault/Failure Summary
- Device List
- Generic Models
- Device Type Performance
- IPL List
- Tier III Summary
- Tier III Scorecard
- Tier III Data
- Bad Actors
Reports:
- General
- Availability
- Bypass Events
- Bypass Override Procedure Worksheets
- Current Bypasses
- Demand Events Recorded
- Demand Rates
- Device Event Summary: INPUTS
- Device Event Summary: OUTPUTS
- Device List
- Device Summary: INPUTS
- Device Summary: OUTPUTS
- Devices Last Event Failed
- Devices with Events Prior to Install Date
- Devices with No Events
- Equipment Scorecard
- Event Type Summary
- Failure Distribution By Generic Model
- Failure Distribution By Generic Model Graph
- Failure Distribution by Site
- Failure Rates
- Failure Summary
- Generic Models/Prior Use Statistics
- INPUTS Failure Rates
- Install Count and Hours in Service by Gen. Model
- IPL List
- List Interlocks and MPs
- List Interlocks/Inputs/Outputs and MPs
- List SIFs and TGs
- Lists Alarms and TGs
- Lists BPCS and TGs
- OUTPUTS Failure Rates
- Periodic Performance Report
- PIU Dataset Change Report
- Proven In Use Statistics
- SIF/SIS/Logic Solver with no Test Groups
- SIFs with TGs Test Intervals
- Specific Input Devices By Unit
- Specific Output Devices By Unit
- Spurious Trip
- Test Group IPLs and Devices
- Test Groups by Overdue and On Schedule
- Test Groups with no I/O
- Test Groups with no Last Test date
- Tests Groups Due
- Tier III Summary
- Tier Scorecard
- Upcoming Tests
- Upcoming Tests Look Ahead
- Operational
- Bypasses Summary/Status
- Demands
- Fault/Failure Summary/Status
- Testing
- Test Group List
- Test Summary/Status Reports
- Administration
- Device Event Summary
- Device Performance by Type
- Device Service Status
- Devices Without Generic Model
- Devices Without Model No./Serial No./Service Class
- Devices Without Test Groups
- Functions Service Status
- Functions Without Devices
Build a Safer System from the Start
The SLM HAZOP LOPA report provides instant visibility into which HAZOP scenarios require a LOPA and which have been completed—ensuring no gaps between analysis and action.